About Reactor
A control desk for a made-up pressurised-water reactor of the kind most of the world's nuclear power comes from: 3,000 MW of heat in the core, about 1,000 MW of electricity at the generator. Water at 155 bar (15.5 MPa) is pumped through the core, where it is heated from 292 °C to 324 °C without boiling, then through four steam generators, where it boils the water of a second circuit. That steam turns the turbine. This is a teaching model, not a real plant : the numbers are typical of such plants, the sums are simplified, and it is no guide to any real reactor.
CONTROL ROOM : pick a scenario and press START . The STEPS card above the recorders walks you through the job one step at a time: each step ticks itself off when it's done, the controls it needs glow, and the numbered buttons let you read any step again. Point at anything on the desk and the line under the card says what it is, or why it's greyed out. Time runs at the speed you pick (×1 is real time; ×3600 is an hour a second) and PAUSE stops it (RESUME carries on). The desk has the controls a reactor operator has: the rods (AUTO holds the average coolant temperature on its programme; MANUAL moves the control group to the steps you set, at 48 steps a minute), boron in the water (slow: BORATE adds it, DILUTE takes it out), the four coolant pumps and their speed, the turbine steam valve (it moves at most 5% a minute) and the guarded SCRAM . The mimic shows the pipework with its temperatures and pressures; the annunciator windows flash until you press ACK ; the pen recorders draw the whole run. The protection trips the reactor by itself on high flux (109%), a period shorter than 10 s, high pressure (16.5 MPa), low pressure (13.0 MPa), too little flow for the power, a low rough DNB ratio, a turbine trip at power and low steam generator water. Rod withdrawal is blocked on a period under 20 s. Each run ends with a DEBRIEF .
AT THE DESK: THE TEXTBOOK hands the desk to an automatic operator that does what the training manuals say (rods in automatic, boron to keep the rods in their band, the turbine kept under its limits, the pump started once its fault is cleared, a slow approach to critical, then the turbine synchronised and loaded at about 3% a minute, with the rods left on MANUAL until the turbine is taking steam). When you run a scenario yourself, the textbook runs the same one alongside you and draws a pencil line on the recorders; the debrief compares the two. You can swap at any time: TAKE OVER from the textbook, or hand the desk back to it, and the run carries on.
WHY DELAYED NEUTRONS : make a sudden change of reactivity and see the power follow it, with and without the 0.65% of neutrons that come late. XENON : how the xenon-135 in the fuel builds after the power falls and burns away when it rises, and when that stops a restart. AFTER SHUTDOWN : the heat that keeps coming after the chain reaction stops.
THE STORY
Enrico Fermi's team started the first reactor, Chicago Pile-1, on 2 December 1942. It could be controlled by hand only because a small share of the neutrons from fission come seconds to about a minute later, from the decay of some of the fission products; Richard Roberts and colleagues in Washington had found these delayed neutrons in 1939. The six groups used here are G. R. Keepin's measurements for uranium-235, published with Wimett and Zeigler in 1957.
Xenon caught out the first big production reactor, at Hanford in September 1944: it started, ran for a few hours, then faded and shut itself down, and started again after half a day. John Wheeler worked out that a fission product was swallowing neutrons, and it turned out to be xenon-135. The reactor had been built with spare fuel channels, which were loaded so it could overcome the xenon.
Pressurised-water reactors grew out of submarine engines in the 1950s. In them, if the water gets hotter or boils, fewer neutrons are slowed down and the power falls: the reactor partly steadies itself. Not every design behaves so. In the RBMK, a Soviet design cooled by water boiling in channels through graphite, steam bubbles take away water that soaks up neutrons while the graphite keeps slowing them, so more steam means more power: a positive void coefficient. At Chernobyl unit 4 on 26 April 1986, during a test at low power, with the reactor poisoned by xenon after an earlier spell at reduced power and most of its rods withdrawn, the power rose, the coolant boiled and the rise fed itself faster than the rods could go in; the design of the rods' tips first added reactivity as they entered. The International Atomic Energy Agency's safety group set this out in its report INSAG-7 (1992). RBMKs still running were changed afterwards.
Decay heat is why cooling matters after a shutdown. At Three Mile Island in 1979 the reactor tripped as it should; the core was damaged hours later, by decay heat, after cooling water had been lost through a relief valve that stayed open. At Fukushima Daiichi in 2011 the running reactors shut down on the earthquake; the tsunami then took out the diesels and the power supplies for cooling, and decay heat melted the fuel in three of them. Katharine Way and Eugene Wigner published the rule of thumb used here in 1948.
HOW IT WORKS
Neutrons : the point kinetics equations with six delayed groups (β = 0.0065, prompt generation time 20 µs), stepped every 0.1 s of plant time with an implicit method that copes with the very fast prompt neutrons. Reactivity is in pcm (one hundred-thousandth); 650 pcm (one "dollar") is prompt critical. The period is how long the power takes to grow by a factor of e (2.718). The WHY DELAYED NEUTRONS chart uses the exact solution (the seven roots of the inhour equation).
Reactivity = what the core has with every rod out and no boron or xenon, less the rods (each bank's worth follows the usual S-shaped curve; banks A to D overlap 100 steps; the shutdown banks hold 4,500 pcm), less 9 pcm for each ppm of boron, less the xenon, plus the temperature effects: −2.8 pcm per °C of fuel (Doppler) and −28 pcm per °C of coolant in the middle of the fuel cycle, −50 at the end, so a hotter core is less reactive. Going from no load to full load uses up about 1,500 pcm.
Heat : the fuel (30 MJ per °C) passes heat to the coolant; the coolant is two lumps (hot leg and cold leg) linked by the flow; the steam generators pass heat across their tubes; the secondary side holds its pressure on the saturation line (IAPWS-IF97 formula). The turbine takes steam in proportion to valve opening and steam pressure. The steam dump to the condenser takes over when the turbine is off and holds the no-load temperature (292 °C); atmospheric relief valves open at 7.9 MPa. The pressuriser rises when the water expands into it and falls when it shrinks; heaters, spray and a relief valve hold it near 15.5 MPa. Pumps coast down on their flywheels; with none running, natural circulation (hot water rising, cool water sinking) carries a few per cent of normal flow.
Xenon : iodine-135 (6.57 h half-life) is made by fission and decays into xenon-135 (9.14 h), which also comes straight from fission and is burned by neutrons; 2,800 pcm at full power. Decay heat : 13 groups fitted to Way and Wigner's rule after a year at power, 6.5% of the heat at steady power.
What it leaves out : the core is one point (no hot spots except the rough tilt from a stuck rod), there is no samarium, the moderator coefficient doesn't change with boron, the DNB ratio is a rough trend, not a real correlation, the steam generators have no level swell, and the pumps and the textbook controller are simpler than real ones. The made-up plant has variable-speed coolant pumps; most real ones run at one speed. The power-to-flow trip (power above 1.08 × flow) is used on some plants; others trip on low flow in any loop. Real plants have many more trips and permissives, and operators work from written procedures.